Details
-
Bug
-
Resolution: Unresolved
-
Low
-
None
-
5.4.16
-
Severity 3 - Minor
-
Description
Issue Summary
This is reproducible on Data Center: yes
Â
Testing Requirements | Version | Affected Version(Yes / No) |
---|---|---|
Customers Reported Version | N/A | Â |
Most Recent Bug-Fix Release | Â | Â |
Previous Major Release | Â | Â |
Most Recent LTS | Â | Â |
Previous Supported LTS | 5.4 LTS | Yes (can reproduce edit. Clone seems flaky) |
Steps to Reproduce
- Go to an Assets schema and create at least one object
- Make sure that the view is set to "List view"
- Use the "Edit" or "Clone" context menu items (accessed through the cog action menu on the right of the list item) by using the keyboard
Expected Results
Edit / clone dialogs open as when using the mouse
Actual Results
Sometimes, on faster network connection or when pressing the ENTER key for longer than required, while triggering the Edit / Clone options, the dialogs will open, and submit straight away, actioning the edit / clone save logic.
Workaround
Use the mouse to work around this or make sure to press the ENTER key quickly / use network throttling.