Bug
-
Resolution: Unresolved
-
Low
-
None
-
5.2.0
-
Severity 3 - Minor
-
Issue Summary
On "Create directory connector"page, the instructions related to the form fields are not associated.
Note: The same issue was found on "Add new group" page.
Steps to Reproduce
- Using screen reader, navigate to the mentioned form fields.
- Listen that the instruction is not announced along with label text of mentioned form fields.
Screenshot
Actual Results
The instruction "The connection URL to use when connecting to the directory server. For example ldap://localhost:389" and "Security protocol to use when connecting to the directory server." are not associated with their respective form fields "URL" and "SSL". As a result, screen reader users might miss out important instructions.
Expected Results
The screen reader should announce the instruction along with label text.
Apply the following changes:
• Add "aria-describedby" attribute to the form field.
• Reference the "id" value of the element used to display the instruction text in the "aria-describedby" attribute.
Workaround
Currently there is no known workaround for this behavior. A workaround will be added here when available
Environment
MacBook Pro (16-inch, 2021)
macOS: Sonoma 14.1.
Chrome - Version 118.0.5993.70 (Official Build) (arm64)
Firefox- Version 92.0 (64-bit)
Safari- Version 17.0 (19616.1.27.211.1)
JAWS- Version 2023
NVDA- Version 2021.2
Voiceover - Version Latest
[CWD-6150] Create directory connector: Instruction not associated with form field
Status | Original: Needs Triage [ 10030 ] | New: Ready for Development [ 10049 ] |
Labels | Original: 1.3.1 ax-at-user ax-bug ax-crowd-dc-vpat ax-crowd-dc-vpat-createdirectoryconnecter ax-crowd-dc-vpat-pg03 ax-qa level-A wcag21 | New: 1.3.1 ax-at-user ax-bug ax-crowd-dc-vpat ax-crowd-dc-vpat-addnewgroup ax-crowd-dc-vpat-createdirectoryconnecter ax-crowd-dc-vpat-pg03 ax-crowd-dc-vpat-pg10 ax-qa level-A wcag21 |
Description |
Original:
h3. Issue Summary
On "Create directory connector"page, the instructions related to the form fields are not associated. h3. Steps to Reproduce # Using screen reader, navigate to the mentioned form fields. # Listen that the instruction is not announced along with label text of mentioned form fields. h3. Screenshot !Screenshot 2023-11-16 at 12.13.18 PM.png|thumbnail! h3. Actual Results The instruction "The connection URL to use when connecting to the directory server. For example ldap://localhost:389" and "Security protocol to use when connecting to the directory server." are not associated with their respective form fields "URL" and "SSL". As a result, screen reader users might miss out important instructions. h3. Expected Results The screen reader should announce the instruction along with label text. Apply the following changes: • Add "aria-describedby" attribute to the form field. • Reference the "id" value of the element used to display the instruction text in the "aria-describedby" attribute. h3. Workaround Currently there is no known workaround for this behavior. A workaround will be added here when available h3. Environment MacBook Pro (16-inch, 2021) macOS: Sonoma 14.1. Chrome - Version 118.0.5993.70 (Official Build) (arm64) Firefox- Version 92.0 (64-bit) Safari- Version 17.0 (19616.1.27.211.1) JAWS- Version 2023 NVDA- Version 2021.2 Voiceover - Version Latest |
New:
h3. Issue Summary
On "Create directory connector"page, the instructions related to the form fields are not associated. *Note:* The same issue was found on "Add new group" page. h3. Steps to Reproduce # Using screen reader, navigate to the mentioned form fields. # Listen that the instruction is not announced along with label text of mentioned form fields. h3. Screenshot !Screenshot 2023-11-16 at 12.13.18 PM.png|thumbnail! h3. Actual Results The instruction "The connection URL to use when connecting to the directory server. For example ldap://localhost:389" and "Security protocol to use when connecting to the directory server." are not associated with their respective form fields "URL" and "SSL". As a result, screen reader users might miss out important instructions. h3. Expected Results The screen reader should announce the instruction along with label text. Apply the following changes: • Add "aria-describedby" attribute to the form field. • Reference the "id" value of the element used to display the instruction text in the "aria-describedby" attribute. h3. Workaround Currently there is no known workaround for this behavior. A workaround will be added here when available h3. Environment MacBook Pro (16-inch, 2021) macOS: Sonoma 14.1. Chrome - Version 118.0.5993.70 (Official Build) (arm64) Firefox- Version 92.0 (64-bit) Safari- Version 17.0 (19616.1.27.211.1) JAWS- Version 2023 NVDA- Version 2021.2 Voiceover - Version Latest |
Description |
Original:
h3. Issue Summary
On "Create directory connector"page, the instructions related to the form fields are not associated. h3. Steps to Reproduce # Using screen reader, navigate to the mentioned form fields. # Listen that the instruction is not announced along with label text of mentioned form fields. h3. Actual Results The instruction "The connection URL to use when connecting to the directory server. For example ldap://localhost:389" and "Security protocol to use when connecting to the directory server." are not associated with their respective form fields "URL" and "SSL". As a result, screen reader users might miss out important instructions. h3. Expected Results The screen reader should announce the instruction along with label text. Apply the following changes: • Add "aria-describedby" attribute to the form field. • Reference the "id" value of the element used to display the instruction text in the "aria-describedby" attribute. h3. Workaround Currently there is no known workaround for this behavior. A workaround will be added here when available Environment MacBook Pro (16-inch, 2021) macOS: Sonoma 14.1. Chrome - Version 118.0.5993.70 (Official Build) (arm64) Firefox- Version 92.0 (64-bit) Safari- Version 17.0 (19616.1.27.211.1) JAWS- Version 2023 NVDA- Version 2021.2 Voiceover - Version Latest |
New:
h3. Issue Summary
On "Create directory connector"page, the instructions related to the form fields are not associated. h3. Steps to Reproduce # Using screen reader, navigate to the mentioned form fields. # Listen that the instruction is not announced along with label text of mentioned form fields. h3. Screenshot !Screenshot 2023-11-16 at 12.13.18 PM.png|thumbnail! h3. Actual Results The instruction "The connection URL to use when connecting to the directory server. For example ldap://localhost:389" and "Security protocol to use when connecting to the directory server." are not associated with their respective form fields "URL" and "SSL". As a result, screen reader users might miss out important instructions. h3. Expected Results The screen reader should announce the instruction along with label text. Apply the following changes: • Add "aria-describedby" attribute to the form field. • Reference the "id" value of the element used to display the instruction text in the "aria-describedby" attribute. h3. Workaround Currently there is no known workaround for this behavior. A workaround will be added here when available h3. Environment MacBook Pro (16-inch, 2021) macOS: Sonoma 14.1. Chrome - Version 118.0.5993.70 (Official Build) (arm64) Firefox- Version 92.0 (64-bit) Safari- Version 17.0 (19616.1.27.211.1) JAWS- Version 2023 NVDA- Version 2021.2 Voiceover - Version Latest |
Attachment | New: Screenshot 2023-11-16 at 12.13.18 PM.png [ 447645 ] |
Description |
Original:
h3. Issue Summary
This is reproducible on Data Center: (yes) / (no) h3. Steps to Reproduce # Step 1 # Step 2 # Step h3. Expected Results Test h3. Actual Results Test h3. Workaround Currently there is no known workaround for this behavior. A workaround will be added here when available |
New:
h3. Issue Summary
On "Create directory connector"page, the instructions related to the form fields are not associated. h3. Steps to Reproduce # Using screen reader, navigate to the mentioned form fields. # Listen that the instruction is not announced along with label text of mentioned form fields. h3. Actual Results The instruction "The connection URL to use when connecting to the directory server. For example ldap://localhost:389" and "Security protocol to use when connecting to the directory server." are not associated with their respective form fields "URL" and "SSL". As a result, screen reader users might miss out important instructions. h3. Expected Results The screen reader should announce the instruction along with label text. Apply the following changes: • Add "aria-describedby" attribute to the form field. • Reference the "id" value of the element used to display the instruction text in the "aria-describedby" attribute. h3. Workaround Currently there is no known workaround for this behavior. A workaround will be added here when available Environment MacBook Pro (16-inch, 2021) macOS: Sonoma 14.1. Chrome - Version 118.0.5993.70 (Official Build) (arm64) Firefox- Version 92.0 (64-bit) Safari- Version 17.0 (19616.1.27.211.1) JAWS- Version 2023 NVDA- Version 2021.2 Voiceover - Version Latest |
Labels | New: 1.3.1 ax-at-user ax-bug ax-crowd-dc-vpat ax-crowd-dc-vpat-createdirectoryconnecter ax-crowd-dc-vpat-pg03 ax-qa level-A wcag21 |