Details
-
Bug
-
Resolution: Duplicate
-
Low
-
None
-
7.1.1
-
None
-
2
-
Severity 3 - Minor
-
Description
Problem
After upgrading to Confluence 7.1.1, the periodic log scanner stopped working
Environment
Confluence 7.1.1
Google mail server (it might happen to other mail servers as well)
Steps to Reproduce
Setup a mail server on Confluence and configure the periodic scan by going to administration -> Troubleshooting and support tools -> Periodic scan
The email will not be sent at the specified timestamp and the warning will appear in the logs
Expected Results
An email should be sent at the specified time
Actual Results
No email is sent
Workaround
No workaround found
Notes
This warning can be found in logs
2019-12-07 01:01:55,784 WARN [Caesium-1-3] [impl.schedule.caesium.JobRunnerWrapper] runJob Scheduled job HerculesScheduledScanTask#HerculesScheduledScanTask completed unsuccessfully with response JobRunnerResponse[runOutcome=FAILED,message='AopInvocationException: AOP configuration seems to be invalid: tried calling method \[public abstract void com.atlassian.core.task.MultiQueueTaskManager.addTask(java.lang.String,com.atlassian.core.task.Task\)] on target [com.atlassian.core.task.DefaultMulti']