Okta : Provision large group membership in batches

XMLWordPrintable

    • 5

      When provisioning a group with 10,000 members or more via Okta, the initial sync will fail with the following error.

      Resource [GROUP] Exceeded group member limit of 10000 per group operation; please use additional group patch operation to add/replace/remove members
      

       

       

      Suggestion :
      Please coordinate with Okta to set the following configurations to be by default for the SCIM application in Okta. This will allow the group membership to be provisioned in batches. 

      • Custom Patch Batch Size=1000
      • Separate Group and Membership Creation

       

      Workaround
      Option 1 : Decrease the Okta group membership below 10000 and provision the group to Atlassian cloud. After the group has been provisioned, increase the group membership as needed.

      Option 2 : Please reach out to Okta support directly and request for the following configurations to be applied to the Okta SCIM application encountering the error.

      • Custom Patch Batch Size=1000
      • Separate Group and Membership Creation

            Assignee:
            Ryan Van
            Reporter:
            Ramon M (Inactive)
            Votes:
            4 Vote for this issue
            Watchers:
            11 Start watching this issue

              Created:
              Updated: